Engineer 418 & 818 User Manual Page 17
Connection instructions for Phoenix terminal blocks
To connect the Phoenix terminal blocks, always use the following procedure:
strip the jacket 20mm
strip the wires 7 mm
DO NOT pre tin the wires
cover the ground wire with a heat shrink sleeving
put the wire up to the plastic sleeve in the terminal block
use a small flathead screwdriver to firmly close the contact
make a strain relief so no stain is on the connection
for suitable wire thickness, please refer to the table below
Conductor cross section solid min. 0.2 mm
2
Conductor cross section solid max. 2.5 mm
2
Conductor cross section stranded min. 0.2 mm
2
Conductor cross section stranded max. 2.5 mm
2
Conductor cross section stranded, with ferrule without plastic sleeve min. 0.25 mm
2
Conductor cross section stranded, with ferrule without plastic sleeve max. 2.5 mm
2
Conductor cross section stranded, with ferrule with plastic sleeve min. 0.25 mm
2
Conductor cross section stranded, with ferrule with plastic sleeve max. 2.5 mm
2